— 12 —
NOTE
If you do not want to use a hardware DIP switch to set up the Turbo
Ring, you can use a web browser, Telnet, or console to disable this
function.
EDS-510A Series DIP Switches
12
------
MASTER
COUPLER
TURBO
RING
34
The default setting for each DIP Switch is OFF. The
following table explains the effect of setting the DIP
Switches to the ON positions.
DIP Switch Setting Description
------
Serves no function (reserved for future use).
ON
Enables the EDS-510A to be the Ring Master in a
Turbo Ring topology, and enables the Turbo Ring
break warning. If the EDS-510A is the Master of
this Turbo Ring, and the Turbo Ring is broken, the
relay will form an open circuit.
MASTER
OFF
Disables the EDS-510A from being the Ring
Master in a Turbo Ring topology, and disables the
Turbo Ring break warning.
ON
Enables the Turbo Ring Coupling function. Use
port 7 and G1 of EDS-510A to form the Ring
Coupler path.
COUPLER
OFF Disables the Turbo Ring coupling function.
ON
Enables plug-and-play Turbo Ring redundancy.
Ports G2 and G3 of EDS-510A are used to form a
Turbo Ring.
TURBO
RING
OFF
Disables the plug-and-play Turbo Ring
redundancy function.
NOTE
You must enable the Turbo Ring function first before using the DIP
switch to activate the Master and Coupler functions.
NOTE
If you do not enable any of the EDS-510A switches to be the Ring
Master, the Turbo Ring protocol will automatically choose the
EDS-510A with the smallest MAC address range to be the Ring
Master. If you accidentally enable more than one EDS-510A to be
the Ring Master, these EDS-510A switches will auto-negotiate to
determine which one will be the Ring Master.