NPort 5600 Series User’s Manual Configuring NPort Administrator
5-22
Connect/Disconnect Description
Startup/None
(default)
A TCP connection will be established on startup, and will remain
active indefinitely.
Any Character/None
A TCP connection will be established when any character is
received from the serial interface, and will remain active
indefinitely.
Any Character/
Inactivity Time
A TCP connection will be established when any character is
received from the serial interface, and will be disconnected when
the Inactivity time out is reached.
DSR On/DSR Off
A TCP connection will be established when a DSR “On” signal is
received, and will be disconnected when a DSR “Off” signal is
received.
DSR On/None
A TCP connection will be established when a DSR “On” signal is
received, and will remain active indefinitely.
DCD On/DCD Off
A TCP connection will be established when a DCD “On” signal is
received, and will be disconnected when a DCD “Off” signal is
received.
DCD On/None
A TCP connection will be established when a DCD “On” signal is
received, and will remain active indefinitely.
ATTENTION
Up to 4 connections can be established between NPort and hosts. The connection speed or
throughput may be low if one of the four connections is slow, since the 1 slow connection will
slow down the other 3 connections.
ATTENTION
The “Destination IP address” parameter can use both IP address and Domain Name. For some