Command Values Description
Sr? r = 0-11, 13, Reads value of Register “r” and displays
15-19, 24-26, value in 3-digit Decimal format.
30, 32 or 34...
$SBn n = speed 2834 Series:
$SB300 selects 300 bps at serial port.
$SB1200 selects 1200 bps at serial port.
$SB2400 selects 2400 bps at serial port.
$SB4800 selects 4800 bps at serial port.
$SB9600 selects 9600 bps at serial port.
$SB19200 selects 19,200 bps at serial port.
$SB38400 selects 38,400 bps at serial port.
* $SB57600 selects 57600 bps at serial port.
$SB115200 selects 115200 bps at serial port.
1432 Series:
$SB300 selects 300 bps at serial port.
$SB1200 selects 1200 bps at serial port.
$SB2400 selects 2400 bps at serial port.
$SB4800 selects 4800 bps at serial port.
$SB9600 selects 9600 bps at serial port.
$SB19200 selects 19,200 bps at serial port.
$SB38400 selects 38,400 bps at serial port.
* $SB57600 selects 57600 bps at serial port.
932 Series:
$SB300 selects 300 bps at serial port.
$SB1200 selects 1200 bps at serial port.
$SB2400 selects 2400 bps at serial port.
$SB4800 selects 4800 bps at serial port.
$SB9600 selects 9600 bps at serial port.
$SB19200 selects 19,200 bps at serial port.
* $SB38400 selects 38400 bps at serial port.
&SFn n = 0 or 1 * &SF0 selects DSR follows CD.
&SF1 selects DSR independent.
&Sn n = 0, 1 or 2 &S0 forces Data Set Ready On.
* &S1 lets Data Set Ready act normally.
&S2 Data Set Ready drop is regulated by S24 on
disconnect.
$SPn n = 0 or 1 * $SP0 disables UUCP Spoofing
$SP1 enables UUCP Spoofing
T Modem will tone-dial numbers following the T.
&Tn n = 4 or 5 &T4 means Enable Response to Request for
Remote Digital Loopback.
* &T5 means Disable Response to Request for
Remote Digital Loopback.
#Tn n = 0 or 1 #T0 turns off Trellis Coded Modulation
* #T1 turns on Trellis Coded Modulation
* Factory Default Setting