Multitech MT5634ZBA-USB Modem User Manual


 
28
MT5634ZBA-USB User Guide
Command: &Tn V.54 Test Commands
Values: n = 0, 1, 3 or 6
Default: None
Description:&T0 Abort. Stop any test in progress.
&T1 Local analog loopback test.
&T3 Local digital loopback test.
&T6 Remote digital loopback test.
Note: To stop a test, you must use the escape sequence (+++AT) before typing AT&T0.
Command: &V Display Current Settings
Values: n/a
Description: Displays the active modem settings, including the callback security settings if callback se-
curity is enabled. If the setup password has been entered, it also displays the callback secu-
rity passwords.
Command: &Wn Store Current Configuration
Values: n = 0
Default: None
Description:&W0 Stores current modem settings in nonvolatile memory and causes them to be loaded at
power-on or following the ATZ command instead of the factory defaults. See also the &F
command.
&W1 Clears user default settings from nonvolatile memory and causes the factory defaults to be
loaded at power-on or following the ATZ command.
Command: &Yn Select Stored Configuration for Hard Reset
Values: n = 0
Default: 0
Description:&Y0 Select stored configuration 0 on power-up. (For backward compatibility with some soft-
ware.)
&Y1 Not supported—responds ERROR.
Command: &Zy=x Store Dialing Command
Values: y = 0–1
x = Dialing command
Default: None
Description: Stores dialing command x in memory location y. Dial the stored number using the com-
mand ATDS=y.
Command: \An Select Maximum MNP Block Size
Values: n = 0, 1, 2, or 3
Default: 3
Description:\A0 64-character maximum.
\A1 128-character maximum.
\A2 192-character maximum.
\A3 256-character maximum.
Command: \Bn Transmit Break
Values: n = 0–9 in 100 ms units
Default: 3
Description: In non-error-correction mode only, sends a break signal of the specified length to a remote
modem. Works in conjunction with the \K command.