Multi-Tech Systems MT2834BLR Network Card User Manual


 
51
Chapter 4 - Commands
S25
DTR Dropout Time
Unit: 100 mSec.
Range: 0, 1 through 255
Default: 0
Description: Defines DTR dropout time. 0 default equals 50ms.
S26
Failed Password Attempts
Unit: 1 failed attempt
Range: 0-255
Default: 0
Description: Counts the number of times there has been a failed
password attempt.
S29
Local Inactivity Timer
Unit: minutes
Range: 1-255
Default: 20
Description: Defines the amount of idle time that can elapse between
AT commands after the SETUP password has been
entered.
S30
Inactivity Timer
Unit: 1 minute
Range: 0-255
Default: 0
Description: Inactivity timer used to disconnect the modem.
S32
Time Elapse for Escape Sequence
Unit: 1 second
Range: 0-255
Default: 20
Description: Sets the duration in which modem waits for a <CR> to be
entered during escape sequence execution.
S34
Buffer Length of Command Mode...After On-line Escape Sequence
Unit: ASCII Character
Range: 0-60
Default: 10
Description: Sets buffer length of command mode after on-line escape
sequence.