Multi-Tech Systems MT2834BR Network Card User Manual


 
50
Chapter 4 - Commands
S10
Carrier Loss Disconnect Delay Time
Unit: 100 mSec.
Range: 0-255
Default: 7
Description: Sets the time a carrier signal must be lost before the
modem disconnects.
S11
Tone Dialing: Tone Spacing and Duration
Unit: 1 mSec.
Range: 1-255, 80-255*
Default: 70, 80*
Description: Sets the time duration of spacing between tone in tone-
dialing.
S13
Remote Configuration Escape Character
Unit: ASCII Character
Range: 0-127
Default: 37 (% sign)
Description: Defines the remote configuration escape character.
S16
Callback Attempts
Unit: 1 Attempt
Range: 1-255
Default: 4
Description: S16 defines the number of attempts allowed after initial
passwords have been exchanged between modems.
S17
Changing Break Time
Unit: 10 mSec.
Range: 0-2.5 sec
Default: 250
Description: S17 defines the break time (space) to local PC.
S24
PBX/CBX Disconnect Drop Time for DSR/CTS/CD
Unit: 50 mSec.
Range: 0-255
Default: 20
Description: Defines DSR/CTS/CD dropout time. The default of 20
equals one second.