Multi-Tech Systems MT5634ZBA-USB Network Router User Manual


 
35
Chapter 4 - AT Commands, S-Registers and Result Codes
Command: %C
n
Data Compression Control
Values:
n
= 0 or 1
Default: 1
Description:%C0 Disable V.42bis/MNP 5 data compression.
%C1 Enable V.42bis/MNP 5 data compression.
Command: %DC
n
AT Command Control
Values:
n
= 0 or 1
Default: 0
Description: %DC0 The modem responds to AT commands.
%DC1 The modem ignores AT commands.
Note: The modem will respond to AT%DC for 10 seconds after power-up.
Command: %E
n
Fallback and Fall Forward Control
Values:
n
= 0, 1, or 2
Default: 2
Description:%E0 Disable fallback and fall forward.
%E1 Enable fallback, disable fall forward.
%E2 Enable fallback and fall forward.
Command: #S
x
Enter Setup Password
Values:
x
= password (1–8 characters, case sensitive)
Default: MTSMODEM
Description: Enters the remote configuration setup password.
Command: #S=
x
Store Setup Password
Values:
x
= password (1–8 characters, case sensitive)
Default: MTSMODEM
Description: Stores a new remote configuration setup password.
Command: +++AT<CR> Escape Sequence
Values: n/a
Description: Puts the modem in command mode (and optionally issues a command) while remaining
online. Type +++AT and up to ten command characters, then press ENTER. Used mostly
to issue the hang-up command: +++ATH<CR>.
Command:%%%AT<CR>Remote Configuration Escape Sequence
Values: n/a
Description: Initiates remote configuration mode while online with remote modem. The remote configu-
ration escape character (%) is defined in register
S13
.