Appendix A Specifications for PCI and PXI Buses
6023E/6024E/6025E User Manual A-10 ni.com
I/O connector
6023E/6024E...................................68-pin male SCSI-II type
6025E...............................................100-pin female 0.05D type
Operating Environment
Ambient temperature ..............................0 to 55 °C
Relative humidity ...................................10 to 90% noncondensing
♦ PXI-6025E only
Functional shock.....................................MIL-T-28800 E Class 3 (per
Section 4.5.5.4.1)Half-sine shock
pulse, 11 ms duration, 30 g peak,
30 shocks per face
Operational random vibration.................5 to 500 Hz, 0.31 g
rms
, 3 axes
Storage Environment
Ambient temperature..............................–20 to 70 °C
Relative humidity ...................................5% to 95% noncondensing
♦ PXI-6025E only
Non-operational random vibration .........5 to 500 Hz, 2.5 g
rms
, 3 axes
Note
Random vibration profiles for the PXI-6025E were developed in accordance with
MIL-T-28800E and MIL-STD-810E Method 514. Test levels exceed those recommended
in MIL-STD-810E for Category 1, Basic Transportation.