National Instruments PXI-8185 Personal Computer User Manual


 
Appendix A Specifications
© National Instruments Corporation A-3 NI PXI-8184/8185 User Manual
Shock and Vibration
Operational shock ..................................30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)
Random vibration
Operating ........................................5 to 500 Hz, 0.3 g
rms
(with solid-state hard drive)
Nonoperating ..................................5 to 500 Hz, 2.4 g
rms
(Tested in accordance with IEC-60068-2-64. Nonoperating test
profile exceeds the requirements of MIL-PRF-28800F, Class B.)
Note For EMC compliance, operate this device with shielded cabling. In addition, all
covers and filler panels must be installed. Refer to the Declaration of Conformity (DoC)
for this product for any additional regulatory compliance information. To obtain the DoC
for this product, visit
ni.com/certification, search by model number or product line,
and click the appropriate link in the Certification column.
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
IEC 61010-1, EN 61010-1
UL 61010-1
CAN/CSA C22.2 No. 61010-1
Note For UL and other safety certifications, refer to the product label or visit
ni.com/certification, search by model number or product line, and click the
appropriate link in the Certification column.