NCR 7837 Scanner User Manual


 
7–3
3
7837 User’s Guide
Retail Symbology Selections
MSI
<Default All MSI Settings>
MSI
On
* Off
Check Character
Different types of check characters are used with MSI bar codes. You can
program the scanner to read only MSI bar codes with Type 10 or Type 11 check
characters.
Default = Validate Type 10, but Don’t Transmit.
When Check Character is set to Validate and Transmit, the scanner will only
read MSI bar codes printed with the specified type check character, and will
transmit this character at the end of the scanned data.
When Check Character is set to Validate, but Don’t Transmit, the unit will only
read MSI bar codes printed
with
the specified type check character, but will not
transmit the check character with the scanned data.
Validate Type 10 and Transmit
* Validate Type 10, but Don’t
Transmit
Validate Type 11, but
Don't Transmit
Validate Type 11 and Transmit