NCR 7883 All in One Printer User Manual


 
NCR RealScan 7883 Installation and Owner Guide
497-0424789 Release F 04/04
13 of 75
the RealScan 7883.
Programming the RealScan 7892
Set the RealScan 7892 communication parameters to match the requirements of the RealScan 7883 auxiliary port.
7892 Programming requirements are provided below:
From standard RS-232 protocol
2 0 5 4 1 5 9600 baud, parity none, 1 stop, 8 data, RTS high wait CTS
1 6 D Program label identifiers
4 0 6 1 C39 – ‘a’
5 0 6 6 C128 – ‘f’
6 0 6 2 Interleaved 2 of 5 – ‘b’
End Label Identifier programming completed
2 3 1 0 D CR (0DH) terminating byte
(2 3 C 1 0 A LF (0AH) terminating byte (CR LF) Include for 7837 format; skip for 7832 format)
Save & Reset
You may also consult the Product Information / Features and Options / Auxiliary RS-232 Port
. For a chart showing the
auxiliary port requirements refer to the NCR 7892 Bi-Modal Presentation Scanner User Guide for information about
programming the RealScan 7892.
RealScan 7832 Programming
Scan the tags listed below from the 7832 Operator’s Guide in order to program the 7832 for communicating with a 7883.
NCR Factory Default
Disable ACK
Select Handshake Input
RealScan 7837 Programming
Program the RealScan 7837 according to the following chart. Refer to the RealScan 7837 User's Guide for more specific
information.
Scan barcodes in order. If a triple beep is emitted from the scanner (7837), start over with the top barcode.