NEC EXP320B Server User Manual


 
7-4 Troubleshooting
POST Error Messages
Powering on the server automatically starts the self-diagnostic program, POST (Power On
Self-Test). When POST detects any error, it displays an error message and its measure on the
display unit. Follow the table below to troubleshoot such errors.
Phoenix BIOS 4.0 Release 6.0.XXXX
:
CPU=Pentium III XXX MHz
0640K System RAM Passed
0127M Extended RAM Passed
WARNING:
02B0: Diskette drive A error.
:
press <F1> to resume, <F2> to SETUP
Message indicating a floppy disk drive erro
r
TIPS:
For error messages on optional PCI boards, refer to the manual provided with those options.
On-screen error message Cause Action
0200 Failure Fixed Disk x Hard disk is faulty
x CPU/IO module is faulty.
x Replace the hard disk.
x Replace the CPU/IO module.
0210 Stuck Key Keyboard connection error
x Disconnect the keyboard and
connect it back again.
x Replace the keyboard.
0211 Keyboard error Keyboard is faulty.
x Disconnect the keyboard and
connect it back again.
x Replace the keyboard.
x If restarting does not help,
replace the CPU/IO module.
0212 Keyboard Controller
Failed
Keyboard controller is faulty.
If restarting the server does not
help, replace the CPU/IO module.
0213 Keyboard locked -
Unlock key switch
Keyboard is locked. Unlock the key switch.
0230 System RAM Failed at
offset
DIMM is faulty.
x Replace DIMM.
x Replace the CPU/IO module.
0231 Shadow RAM Failed at
offset
Shadow RAM is faulty.
x Replace DIMM.
x Replace the CPU/IO module.
0232 Extended RAM Failed
at address line
Extended RAM is faulty.
x Replace DIMM.
x Replace CPU/IO module.
0233 Memory type mixing
detected
Memory of the different types
is installed.
Memory of the different types is
installed. Replace DIMM with
appropriate one.
0250 System battery is dead
-Replace and run
SETUP
System battery is dead.
x Replace system battery.
x Replace CPU/IO module.