Net2Phone Max 410 Network Card User Manual


 
Max 410/420/430 User’s Guide – Appendix
74
SYMPTOM POSSIBLE
CAUSE
CORRECTIVE
ACTION
Overheating Check ventilation Unit shuts off
after operating
for some time
Faulty N2P
Max
410/420/430
Contact Technical
Service Center or
your reseller
Console fault Reset/replace
console
Software error Repeat power-up
procedure
Console
screen display
freezes
Faulty N2P
Max
410/420/430
Contact Technical
Service Center or
your reseller
Network Problems
When I attempt to connect to my Max 410/420/430
through a serial cable connection, I do not see any
text, or the text that appears is distorted.
Make sure the connection settings are as
follows:
Baud rate
19200
Parity
None
Character size
8
Stop Bit
1
Flow Control
None
Make sure the serial cable is connected and
fastened to both the Max 410/420/430 and
your computer.
My network supports DHCP, but my Max 410/420/430
cannot obtain correct network settings.
Make sure DHCP is enabled.