17
SPECIFICATIONS
SPECIFICATIONS
AC OUTLETS TECHNICAL SPECIFICATIONS
UL 1449 Clamping Rating ............................330 Volts (lower value is better)
ANSI/IEEE 100 kHz Ring Wave Test............<40 volts above peak standard line voltage
Response time ..............................................Instantaneous [<1 nanosecond (<1 billionth of a second)]
Surge Voltage................................................Tested to 6,000 Volts
Energy dissipation ........................................1550 Joules
Line voltage ..................................................120VAC 15A, 50/60 Hz
Peak impulse current....................................100,000 Amps
Protection Modes..........................................Line to Neutral, Line to Ground, Neutral to Ground
EMI/RFI noise reduction ..............................Up to 60dB (99.9%) 100 kHz to 100 MHz
TECHNICAL SPECIFICATIONS FOR EACH COAX CIRCUIT
Clamping level ..............................................70 Volts
Response time ..............................................Instantaneous (<75 nanoseconds)
Energy dissipation ........................................340 Joules
Peak impulse current....................................20,000 Amps
Connections ..................................................Machined, gold-plated Female F-connectors with Teflon Dielectric
Net Weight
..................................................
4 lbs.
Dimensions ............................................Width: 8-1/4"; Height: 7-3/8"; Depth: 2-1/2"