Nortel Networks 114200-E Network Router User Manual


 
Requirements for European Operation
114200-E Rev 00
D-3
ARN Expansion Modules Safety Status
ARN expansion modules are upgrade options that provide an additional
synchronous interface. These options can be installed in any ARN model.
Table D-4
lists the safety status of the interconnection point (COM3, COM4,
COM5, COM6, COM7, COM8, and COM9) provided by each of the expansion
modules (Order Nos. CV0004011, CV0004012, CV0004013, CV0004014,
CV0004015, CV0004026, and CV0004027) to the connection of other equipment.
Synchronous Cabling Requirements
Refer to Figures D-1 through D-6 and Tables D-5 through D-10 for serial interface
cabling information.
Note the following compliance requirements:
V.28 compliance requires an Order No. 7837 or 7934 cable.
V.35 compliance requires an Order No. 7220 or 7932 cable
X.21 compliance requires an Order No. 7224 or 7936 cable.
Table D-4. Safety Status (Order Nos. CV0004011, CV0004012,
CV0004013, CV0004014, CV0004015, CV0004026,
CV0004027)
Port Location Port Description Type of Circuit
COM3, COM4, and COM5,
COM6, COM7, COM8, and
COM9
V.28, X.21, V.35 Telecommunications
network voltage (TNV) at
SELV levels
AUI Ethernet AUI SELV
10Base-T Ethernet 10BASE-T SELV
MAU Token Ring SELV
J2 Host Port SELV
10/100BASE-T Ethernet 10/100BASE-T SELV
JB1 Host Port SELV