Nortel Networks M3310 Network Card User Manual


 
118 Digital Telephone IP Adapter Installation and Administration Guide
Changing configuration settings using Configuration Manager Standard 2.1
911x System Configuration field descriptions
Field Description
Unit ID
Enter a unique number from 1 through 20 to identify
the Digital Telephone IP Adapter unit that you are
configuring and differentiate it between the RLC,
Remote Gateway 9150 unit, and all other remote units
connected to the same RLC. This number:
! must be different from numbers assigned to other
units connected to the same RLC
! must be consistent with the configuration on the
RLC for this unit ID
The default is 1.
Node Name
Enter your site name.
The node name identifies this Digital Telephone IP
Adapter unit in the remote network.
The default is 911x.
DSP Gain
Select the number of decibels (dB) that you want to
add to, or subtract from, the strength of the transmitted
signal before the DSP processes it.
Valid options are 9, 6, 3, 0, -3, -6, -9, -12, and -15.
The default is 0 dB.
Note: Change this setting at the remote site to address
a problem with signal strength at the host site.
Time Offset
Click on the up or down arrows to change the time
zone difference from the host PBX.
The default is 0:00 (0 hours and 0 minutes).
Note: The time can be changed in 15-minute intervals
only.
Emergency Feature
This setting does not apply to Digital Telephone IP
Adapters.