126 COTS Servers
HP DL320 G4 BIOS settings
The Basic Input Output System (BIOS) settings on the HP DL320
G4 server shipped through Nortel are correct. The BIOS settings do
not require adjustment unless they are reset due to a fault or through
maintenance. If a reset of the BIOS settings occurs, check the serial port
option. The HP DL320 G4 BIOS settings can be seen at Table 6 "HP
DL320 G4 default BIOS settings" (page 126). The HP DL320 G4 servers
provide a physical COM1 serial port and a virtual (ILO) COM2 serial port.
If the setting for the serial console port is Auto, output can be directed
to either the COM1 port or COM2 ILO port. Set the serial console port
option to COM1 to ensure the console output goes to the physical COM1.
See “Configure the COM1 serial port on an HP DL320 G4 server” (page
126) for instructions.
The HP DL320 G4 server shipped through Nortel has a default baud rate
of 9600 b/ps and does not require a reset. If an error occurs and you want
to reset the baud rate, or if you want to change to another baud rate, see
“Changing the baud rate on an HP DL320 G4 Signaling Server” (page
128) for instructions.
For information about how to enable or disable the BIOS password on
the HP DL320 G4 server see “Setting the HP DL320 G4 server BIOS
password” (page 130).
Table 6
HP DL320 G4 default BIOS settings
BIOS value
Default setting
Devices and I/O port - serial port A Enabled
Devices and I/O port - baud rate 9600 baud
Devices and I/O port - type of connector 9-pin serial female
Start options - legacy USB support Disabled
Configure the COM1 serial port on an HP DL320 G4 server
Step Action
1 Press Power to boot the server.
The server boots and the HP DL320 G4 boot screen appears.
Nortel Communication Server 1000
Linux Platform Base and Applications Installation and Commissioning
NN43001-315 02.09
29 October 2008
Copyright © 2007–2008 Nortel Networks
.