Nortel Networks NN44200-313 Network Card User Manual


 
Checking the status of the ELAN connection to the PBX (LD 48) 15
—End—
Checking the ELAN interface status of the PBX (LD 137)
Perform the following procedure to check the ELAN interface status.
Step Action
1
Connect to the PBX.
2
Enter LD 137.
3
Enter STAT ELNK. The status of the ELAN interface appears.
Note: If the ELAN interface is not configured, continue to
"Enabling the ELAN interface of the PBX (LD 137)" (page 15).
If it is configured, continue to "Checking the status of the ELAN
connection to the PBX (LD 48)" (page 15).
4
To exit the over lay, enter ****.
—End—
Enabling the ELAN interface of the PBX (LD 137)
Perform the following procedure to enable the ELAN interface. If it is already
enabled, skip to the next procedure.
Step Action
1
Connect to the PBX.
2
Enter LD 137.
3
Enter CHG ELNK ACTIVE NAME, where NAME is the host name
for the primary IP address.
4
To exit the over lay, enter ****.
—End—
Checking the status of the ELAN connection to the PBX (LD 48)
Perform the following procedure to check the status of the ELAN connection
to the PBX.
Nortel CallPilot
Quickstart Guide
NN44200-313 01.02 Standard
5.0 19 May 2008
Copyright © 2007-2008, Nortel Networks
.