Nortel Networks NTRN10AN Server User Manual


 
3-52 Hardware feature descriptions
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
For a complete list of electrical and optical interfaces supported by VTX-48,
VTX-48e and STX-192 equipped OPTera Metro 3500 shelf, refer to Table 3-7
on page 3-52.
Table 3-6
STX and VTX-series compliancy matrix
Card in
Slot 13
Card in
Slot 14
Card types Slot
numbers
Alarm description
VTX-48 VTX-48 OC-192 STS 11 & 12 Circuit Pack Incompatible alarm will be
raised against the cards in slots 11 and 12.
VTX-48 VTX-48 OC-48 STS
OC-12x4 STS
3 through
10
Circuit Pack Incompatible alarm will be
raised against the cards in slots 3 through 10.
VTX-48 VTX-48 OC48 STS
OC-12x4 STS
11 & 12 Circuit Pack Incompatible alarm will be
raised against the cards in slots 11 and 12.
STX-192 STX-192 DS1, E1/DS1,
DS3, DS3VTx12,
DS3/VT, EC1,
OC-48
Any Circuit Pack Incompatible alarm will be
raised against the cards in slots 3 through 10.
STX-192 VTX-48 Any Any Circuit Pack Incompatible alarm will be
raised slot 13 and 14.
VTX-48 STX-192 Any Any Circuit Pack Incompatible alarm will be
raised slot 13 and 14.
Table 3-7
OPTera Metro 3500 Electrical and Optical Interface Support
Electrical & Optical
Interfaces
Maximum number of
facilities per shelf
Number of facilities per
interface
Slots supported
VTX-48 STX-192 VTX-48 STX-192 VTX-48 STX-192
DS1 84 - 12 1 3 - 10
See Note 1
-
DS3x3 12 12 3 3 3 - 10 3 - 10
DS3x12 48 48 12 12 3 - 10 3 -10
DS3VTx12 48 - 12 - 3 - 10 -
EC-1x3
See Note 2
12 12 3 3 3 - 10 3 - 10
EC-1x12 48 48 12 12 3 - 10 3 - 10
OC-3 8 8 1 1 3 - 12 3 - 10
OC-3x4 32 32 4 4 3 - 10 3 - 10