Nortel Networks NTRN10AN Server User Manual


 
Hardware feature descriptions 3-53
Planning and Ordering GuidePart 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
All OPTera Metro 3500 shelves equipped with STX-192 circuit packs will
require they be equipped with:
20 Amp Power Modules (NTN451HA)
Cooling unit assembly (NTN458QA)
Installation of other units then those listed above will result in Equipment
Below Baseline alarm to be raised.
See Table 3-3 on page 3-6 for operational temperature ranges.
OC-12 10 10 1 1 3 - 12
See Note 2
3 - 10
OC-12x4 STS - 32 - 4 - 3 - 10
STM-1x4
See Note 3
32 32 4 4 3 - 10 3 - 10
4x10/100BT (RPR) 32 32 4 4 3 - 10 3 - 10
4x100FX (RPR) 32 32 4 4 3 - 10 3 - 10
2x1000SX
2x1000SX
(GigE RPR)
8 8 2 2 3 - 10 3 - 10
2xGigE/FC-P2P 16 16 2 2 3 - 10 3 - 10
2x10/100BT (P2P) 16 16 2 2 3 - 10 3 - 10
OC-48 2 - 1 - 11 - 12 -
OC-48 STS - 10 - 1 - 3 - 12
OC-192 STS - 2 - 2 - 11 - 12
DSM
See Note 4
12 12 1 1 3 - 10
See Note 5
3 - 10
See Note 5
Note 1:
PSC is in slot 2, DS1 mappers in all other slots.
Note 2:
Only the NTN436AA version of the EC-1x3 is supported
Note 3:
Supported for Japan Configurations only.
Note 4:
Single OPTera Metro 3500 shelf will support 12 protected or unprotected DSM modules.
Note 5:
OC-3 or OC-3x4 interfaces equipped in these slots.
Table 3-7 (continued)
OPTera Metro 3500 Electrical and Optical Interface Support
Electrical & Optical
Interfaces
Maximum number of
facilities per shelf
Number of facilities per
interface
Slots supported