35 – C610/C711 User’s Guide
Tray 2 Config
Tray 3 Config
Note: only present if option
installed
System Adjust Power Save Time
Default: 30
Select from 1/2/3/4/5/10/15/
30/60/120/180 Minutes.
Select by scroll and Enter button.
Sleep Time
Default: 10
Select from 1/2/3/4/5/10/15/
30/60/120/180 Minutes.
Select by scroll and Enter button.
Clearable Warning
Default: ONLINE
Select from: ONLINE/Job. Select
by scroll and Enter button. PS job
only.
Auto Continue
Default: Off
Select from On/Off. Select by
scroll and Enter button.
Manual Timeout
Default: 60
Select from Off/30 seconds/60
seconds.
Select by scroll and Enter button.
Wait Timeout
Default: 40
Select from Off/5/10/20/30/
40/50/60/90/120/150/180/
210/240/270/300 seconds.
Select by scroll and Enter button.
Low Toner
Default: Continue
Select action to take when toner
sensor indicates low toner. Select
from Continue/Stop. Select by
scroll and Enter button.
Jam Recovery
Default: On
Select from On/Off. Select by
scroll and Enter button.
Error Report
Default: Off
Select from On/Off. Select by
scroll and Enter button.
Print Position Adjust
Default: 0.00
Select from X Adjust/Y Adjust/
Duplex X Adjust/Duplex Y
adjust. Select by scroll and Enter
button. Define measurement.
ITEM ACTION EXPLANATION