Opticon CRD972X Scanner User Manual


 
OPL972X/CRD972X OPTICON - 17
2.4 DIP SWITCH SETTINGS
Open the cover of the DIP switches on the bottom
of the cradle in order to reach the DIP switches.
Turn the DIP switch ON by moving it upwards.
Turn the DIP switch OFF by moving it downwards.
Single cradle DIP switch settings:
Multicradle DIP switch settings:
* Set baud rate as in table below.
** In typical use keep cascade switch SW5 off.
User baud rate settings:
DIP
Switch
ON OFF
SW 1 Baud rate * Baud rate *
SW 2 Baud rate * Baud rate *
SW 3 Baud rate * Baud rate *
SW 4 Spare
SW 5 Spare
SW 6 Auto-baud
rate (PC-
controlled)
SW 1, 2, 3
determines
baud rate.
DIP
Switch
ON OFF
SW 1 Baud rate * Baud rate *
SW 2 Baud rate * Baud rate *
SW 3 Baud rate * Baud rate *
SW 4 RS232/
RS485
RS232 only
SW 5 Cascade **
SW 6 RS485
termination
ON
RS485
Termination
OFF
SW 7 Factory
setting
SW 8 Factory
setting
*) Baud rate SW
1
SW
2
SW
3
2400 ON OFF OFF
4800 OFF ON OFF
9600 (default) ON ON OFF
19200 OFF OFF ON
38400 ON OFF ON
57600 OFF ON ON
115200 ON ON ON