Sylvania D3208 Switch User Manual


 
1.32
(33.5 mm)
3.12 (79.2 mm)
6.00 (152.4 mm)
0.161
(4.1 mm)
2.64 (67.1 mm)
4.85 (123.2 mm)
MNW20-00
Architectural Specification Lighting Controls
C
13
For answers to technical questions, call Leviton’s Techline at 1-800-824-3005
MONET
®
WALLPLATE SPECIFICATIONS
Commercial Grade Lighting Controls
Monet Multi-Gang Wallplates
MONET MULTI-GANG WALLPLATE CATALOG NUMBER SYSTEM
Example: MNW31-00W
Add letter to indicate color:
-I (Ivory), -W (White), -A (Almond), -G (Gray)
and -E (Black)
00 = No fins removed
FB = Fins broken off
Number of large-fin devices
Number of small-fin devices
Monet Wallplate
TABLE 1 — FOR INSTALLATIONS WITH NO FINS BROKEN OFF
Wallplate Cat. No. Number of Narrow Wallbox
Fin/Wide Fin Controls Requirements
MNW10-00 1 Narrow 1-Gang
MNW20-00 2 Narrow 3-Gang
MNW30-00 3 Narrow 5-Gang
MNW40-00 4 Narrow 6-Gang
MNW50-00 5 Narrow 9-Gang
MNW60-00 6 Narrow 10-Gang
MNW01-00 1 Wide 1-Gang
MNW02-00 2 Wide 4-Gang
MNW03-00 3 Wide 7-Gang
MNW04-00 4 Wide 9-Gang
MNW11-00 1 Narrow/1 Wide 4-Gang
MNW21-00 2 Narrow/1 Wide 5-Gang
MNW31-00 3 Narrow/1 Wide 7-Gang
MNW41-00 4 Narrow/1 Wide 8-Gang
MNW51-00 5 Narrow/1 Wide 10-Gang
MNW12-00 1 Narrow/2 Wide 6-Gang
MNW22-00 2 Narrow/2 Wide 8-Gang
MNW32-00 3 Narrow/2 Wide 9-Gang
MNW13-00 1 Narrow/3 Wide 9-Gang
MNW23-00 2 Narrow/3 Wide 10-Gang
Maximum Load per Monet Dimmer Multi-Gang with Fins Broken Off
Cat. No. Single 2-Gang More Than
2-Gang
MNE04 400VA (320W) 300VA (240W) 250VA (200W)
MNF07 7.5A 6A 5.3A
MNF10 10A 8A 7A
MNI06 600W 500W 400W
MNI10 1000W 800W 700W
MNI15 1500W 1250W 1000W
MNM06 600VA (450W) 500VA (375W) 400VA (300W)
MNM10 1000VA (800W) 800VA (640W) 700VA (560W)
MNM15 1500VA (1200W) 1250VA (1000W) 1000VA (800W)
MNX10 1000VA (980W) 800VA (784W) 700VA (686W)
MNX15 1500VA (1470W) 1250VA (1225W) 1000VA (980W)
MNX20-7 2000VA (1960W) 1600VA (1568W) 1400VA (1372W)
MNX30-7 3000VA (2940W) 2500VA (2450W) 2000VA (1960W)
TABLE 2 — FOR INSTALLATIONS WITH FINS BROKEN OFF
Wallplate Cat. No. Number of Narrow Wallbox
Fin/Wide Fin Controls Requirements
MNW20-FB 2 Narrow 2-Gang
MNW30-FB 3 Narrow 3-Gang
MNW40-FB 4 Narrow 4-Gang
MNW50-FB 5 Narrow 5-Gang
MNW60-FB 6 Narrow 6-Gang
MNW70-FB 7 Narrow 7-Gang
MNW80-FB 8 Narrow 8-Gang
MNW90-FB 9 Narrow 9-Gang
MNW02-FB 2 Wide 3-Gang
MNW03-FB 3 Wide 5-Gang
MNW04-FB 4 Wide 7-Gang
MNW05-FB 5 Wide 9-Gang
MNW11-FB 1 Narrow/1 Wide 3-Gang
MNW21-FB 2 Narrow/1 Wide 4-Gang
MNW31-FB 3 Narrow/1 Wide 5-Gang
MNW41-FB 4 Narrow/1 Wide 6-Gang
MNW51-FB 5 Narrow/1 Wide 7-Gang
MNW61-FB 6 Narrow/1 Wide 8-Gang
MNW71-FB 7 Narrow/1 Wide 9-Gang
MNW81-FB 8 Narrow/1 Wide 10-Gang
MNW12-FB 1 Narrow/2 Wide 5-Gang
MNW22-FB 2 Narrow/2 Wide 6-Gang
MNW32-FB 3 Narrow/2 Wide 7-Gang
MNW42-FB 4 Narrow/2 Wide 8-Gang
MNW52-FB 5 Narrow/2 Wide 9-Gang
MNW62-FB 6 Narrow/2 Wide 10-Gang
MNW13-FB 1 Narrow/3 Wide 7-Gang
MNW23-FB 2 Narrow/3 Wide 8-Gang
MNW33-FB 3 Narrow/3 Wide 9-Gang
MNW43-FB 4 Narrow/3 Wide 10-Gang
MNW14-FB 1 Narrow/4 Wide 9-Gang
MNW24-FB 2 Narrow/4 Wide 10-Gang
Note: For more information on Fin Removal, refer to the instruction sheet provided
with each Monet device.
Monet multi-gang wallplates are available for every permissible combi-
nation of small fin and large fin dimmers. Tables 1 and 2 can be used
to determine if a specific combination of devices is possible. When
small and large fin devices are combined, all the large fin devices
must be placed to one side and all the small fin devices must be
placed to the other side. In an installation where all the fins are broken
off, do not remove the fins from the dimmers at each of the extreme
ends of the installation.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com