Sylvania D3208 Switch User Manual


 
4.00 (101.6)
3.62
(91.9)
4.30 (109.2)
4.72 (119.9)
4.50 (114.3)
2.06
(52.3)
To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com
Architectural Lighting Control Systems
C
8
POWER EXTENDERS for ARCHITECTURAL LIGHTING CONTROL SYSTEMS
Commercial Grade Lighting Controls
Standard Power Extenders
Power Extenders—PE100, PE200, PE300, PE400
DESCRIPTION CAT. NO. RATING
Extends dimming zone capacity to full 1920W/VA @ 120V PE100-10W Input Voltage: 120V 50/60Hz
for incandescent, magnetic low-voltage, halogen or Load Rating: 1920W/VA
neon/cold cathode lighting. Aluminum heat sink with Load Output Power: phase independent
snap-on white cover of control device
Dimmer Input: 120V 50/60Hz
Extends dimming zone capacity to full 1920VA @ 120V PE200-10W Input Voltage: 120V 50/60Hz
for Mark 10
Powerline
, Hi-Lume
®,
or equivalent Load Rating: 1920VA
dimmable fluorescent ballast. Aluminum heat sink with Load Output Power: phase independent
snap-on white cover of control device
Dimmer Input: 120V 50/60Hz
Extends dimming zone capacity to full 3000VA @ 277V PE200-70W Input Voltage: 277V 50/60Hz
for Mark 10
Powerline
, Hi-Lume
®,
or equivalent Load Rating: 3000VA
dimmable fluorescent ballast. Aluminum heat sink with Load Output Power: phase independent
snap-on white cover of control device
Dimmer Input: 120V 50/60Hz
Extends dimming zone capacity to full control PE300-D0W Input Voltage: 120V AC to
of a 20A circuit with 0–10 V DC Mark 7
®
0–10V
, 277V AC, 60Hz
Lutron 0–10V, OSRAM Sylvania Quicktronic
®
Helios
Load Rating: 20A–2400VA @ 120V AC,
or equivalent ballast. Metallic silver color. 5500VA @ 277V AC
Power Consumption: 6W @ 120V AC,
18W @ 277V AC
Output Ballast Control: 0–10V DC
Dimmer Input: 120V 60Hz
Extends dimming zone capacity to full control of a PE400-10W Input Voltage: 120V AC 50/60Hz
1000W/VA @ 120V AC for electronic low voltage or Load Rating: 1000W/VA
incandescent lighting. Aluminum heat sink with Load Output Power: phase independent
snap-on white cover of control device
Dimmer Input: 120V 60Hz
Mark 10
and Mark 7
are trademarks of the Advance Transformer Company.
Hi-Lume
®
is a registered trademark of the Lutron Electronic Co., Inc.
Auxillary-Zone Network Power Extenders (for D3200 Systems only)
DESCRIPTION CAT. NO. RATING
Enables 2 auxiliary zones on a D3200 Controller/Dimmer PEAUX-12W Input Voltage: 120V AC 50/60Hz
for full control over incandescent, magnetic low-voltage, Load Rating: 1920W/VA total,
or neon/cold cathode lighting. Aluminum heat sink with or 1000W/VA max. per zone
snap-on white cover Load Output Power: phase independent
of control device
Dimmer Input: D3200
Enables 1 auxiliary zone on a D3200 Controller/Dimmer PEAUX-AUW Input Voltage: 230V AC 50/60Hz
for full control over incandescent, magnetic low-voltage, Load Rating: 2400 W/VA total
or neon/cold cathode lighting Aluminum heat sink with Load Output Power: phase independent
snap-on white cover of control device
Dimmer Input: D3200
Enables 1 auxiliary zone on a D3200 Controller/Dimmer PEAU7-M1W Input Voltage: 120-230V 50-60Hz
for full control over Mark 7
0-10V
, OSRAM Output Ballast Control: 0-10V DC
Sylvania Quicktronic Helios, Lutron 0-10V, or equivalent Load Rating: 20A-120V & 10A-230V
ballasts. Aluminum heat sink with snap-on white cover Load Output Power: phase independent
of control device
Dimmer Input: D3200
Power Extender Compatibility
Standard Power Extenders work with any Dimensions Multizone Controller/Dimmer and all Architectural
Systems. Refer to the chart below for compatibility with Leviton Box-Mounted Dimmers.
POWER EXTENDER BOX-MOUNTING DIMMER COMPATIBILITY
PE100-10W Must use 120V 600W Incandescent version of Acenti, IllumaTech, Mural,
True Touch, TouchPoint, ToggleTouch, Sure Slide and Home Controls.
(or 600VA version of Acenti). For Monet, use 120V 600VA Magnetic Low-
Voltage version (requires Neutral wire). For dimmers that include a
Neutral wire, the dimmer Neutral wire must be connected.
PE200-10W Must use 120V 600VA Mark 10 version Acenti, of Monet, IllumaTech,
PE200-70W Mural and TouchPoint. For dimmers that include a Neutral wire, the
dimmer Neutral wire must be connected. For Hi-Lume ballasts, use
incandescent dimmers. PE200-70W is compatible with all 600VA-220V
box-mounted dimmers.
PE300-D0W Must use 120V 600W Incandescent version of Acenti, llumaTech, Mural,
True Touch, TouchPoint, ToggleTouch, Sure Slide and Home Controls.
For Monet, use 120V 600VA Magnetic Low-Voltage version (requires
Neutral wire). For dimmers that include a Neutral wire, the dimmer
Neutral wire must be connected.
PE400-D0W Must use 120V 600W Incandescent version of Acenti, llumaTech, Mural,
True Touch, TouchPoint, Trimatron and Sure Slide Home Controls.
For Monet, use 120V 600VA Magnetic Low-Voltage version (requires
Neutral wire). For dimmers that include a Neutral wire, the dimmer
Neutral wire must be connected.
SPECIFICATIONS AND FEATURES
Standard Power Extenders
• Emulates characteristics of dimmer it
is connected to in terms of dimming
range and resolution
• Low-end trim available for setting
minimum brightness level (PE100,
PE200, PE300)
• PE100, PE200 and PE400 can be
surface or flush mounted using 1900
Box and 2-gang raised cover
• PE300 mounts in 4" square box
APPLICATIONS
Standard Power Extenders
• Works with any D3200 Multizone
Controller/Dimmer to extend load
capacity of any zone
• Extends load capacity of box-mounted
dimmers (see compatibility chart)
• Works with all families of Leviton
Architectural Systems
Network Power Extenders
• Enables a D3200 Multizone
Controller/Dimmer to accommodate
extra loads
• Works with any D3200 Multizone
Controller/Dimmer to extend load
capacity of any zone
TESTING AND CODE COMPLIANCE
• UL Listed (except PEAUX-AUW), CSA
Certified and NOM Certified
• Backed by a Limited Two-Year
Warranty
PE100/200/400/AUX/AU7
PE300-DOW
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com