Panasonic PT-LC75E Projector User Manual


 
ENGLISH-47
Others
46-ENGLISH
Lamp unit replacement procedure
NOTE:
BIf the lamp usage time has passed 2000 hours (when LAMP POWER has
been set to HIGH), the projector will switch to standby mode after
approximately 10 minutes of operation. The steps ) to - on the next
page should thus be completed within 10 minutes.
#Turn off the MAIN POWER
switch according to the
procedure given in “Turning off
the power” on page 25, and
then disconnect the power
cord plug from the wall outlet
and check that the area around
the lamp unit has cooled down.
$Use a Phillips screwdriver to
turn the lamp unit cover fixing
screws at the bottom of the
projector, and then remove the
lamp unit cover from the
projector.
%
Use a Phillips screwdriver to loosen
the two lamp unit fixing screws until
the screws turn freely. Then hold
the handle of the lamp unit and
gently pull it out from the projector.
&Insert the new lamp unit while
making sure that the direction
of insertion is correct, and then
use a Phillips screwdriver to
securely tighten the lamp unit
fixing screws.
Lamp unit cover
Handle
Lamp unit cover fixing screws
Lamp unit fixing screws
Lamp indicator warning
light
On-screen display
The projector will enter
Standby Mode and the
red indicator lamp will
illuminate.
Displayed for 30
seconds. Pressing any
button will clear the
display.
More than 1800 hours
This display cannot be
cleared at all, no matter
which button is pressed.
More than 2000 hours
+Press the ENTER button to
display the OPTION2 screen,
and then use the F and G
buttons to select LAMP
RUNTIME.
,Press and hold the ENTER
button for approximately 3
seconds.
The LAMP RUNTIME will
change to TIME RESET
[POWER OFF].
NOTE:
BIf the MENU button is pressed,
the lamp time resetting screen
will be cancelled.
-Hold down the POWER button
for at least 0.5 seconds or
press the POWER button twice
to turn off the power.
This will reset the cumulative
usage time for the lamp unit to
zero.
'Install the lamp unit cover, and
then use a Phillips screwdriver
to securely tighten the lamp
unit cover fixing screws.
NOTE:
BBe sure to install the lamp unit
and the lamp unit cover securely.
If they are not securely installed,
it may cause the protection circuit
to operate so that the power
cannot be turned on.
(Insert the power cord plug into
the wall outlet and then press
the MAIN POWER switch.
NOTE:
BIf the POWER button on the
projector does not illuminate red
when the MAIN POWER switch is
turned on, turn the MAIN POWER
switch off again and check that
the lamp unit and the lamp unit
cover are securely installed. Then
turn the MAIN POWER switch
back on.
)Press the POWER button so
that a picture is projected onto
the screen.
*Press the MENU button to
display the MAIN MENU
screen, and then press the F
and G buttons to move the
cursor to select “OPTION2”.
MENU
KEYSTONE
PICTURE
POSITION
INDEX WINDOW
SHUTTER
AUDIO
LANGUAGE
OPTION1
OPTION2
SELCT ENTER
OPTION2
BACK COLOR BLUE
FRONT/REAR FRONT
DESK/CEILING DESK
LAMP POWER HIGH
LAMP RUNTIME 1820H
FUNC 1 INDEX
SELCT ESC
OPTION2
BACK COLOR BLUE
FRONT/REAR FRONT
DESK/CEILING DESK
LAMP POWER HIGH
TIME RESET[POWER OFF]
FUNC 1 INDEX
SELCT ESC