ENGLISH-51
Care and maintenance
50-ENGLISH
Lamp unit replacement procedure
#Turn off the MAIN POWER
switch according to the
procedure given in “Turning off
the power” on page 24, and
then disconnect the power
cord plug from the wall outlet
and check that the area around
the lamp unit has cooled down.
$Use a Phillips screwdriver to
turn the lamp unit cover fixing
screws at the bottom of the
projector, and then remove the
lamp unit cover from the
projector.
%
Use a Phillips screwdriver to loosen
the two lamp unit fixing screws until
the screws turn freely. Then hold
the handle of the lamp unit and
gently pull it out from the projector.
&Insert the new lamp unit while
making sure that the direction
of insertion is correct, and then
use a Phillips screwdriver to
securely tighten the lamp unit
fixing screws.
When inserting the new lamp unit, be
sure to push it in at the point A and B.
Lamp indicator warning
light
On-screen display
The projector will enter
Standby Mode and the
red indicator lamp will
illuminate.
Displayed for 30
seconds. Pressing any
button will clear the
display.
More than 1800 hours
This display cannot be
cleared at all, no matter
which button is pressed.
More than 2000 hours
Replacing the lamp unit
Warning
The lamp unit should only be
replaced by a qualified
technician.
When replacing the lamp, allow it
to cool for at least one hour
before handling it.
BThe lamp cover gets very hot,
and contact with it can cause
burns.
Notes on replacing the lamp
unit
BThe light generating lamp is
made of glass, so dropping it or
allowing it to hit hard objects may
cause it to burst. Be careful when
handling the lamp.
BAfter having removed the old
lamp, carelessly discarding it can
cause the lamp to burst. Dispose
of the lamp with the same care
that would be taken with a
fluorescent light.
BA Phillips screwdriver is
necessary for removing the lamp
unit. Make sure that your hands
are not slippery when using the
screwdriver.
Lamp unit replacement
period
The lamp is a consumable product.
Even when the full life of the bulb
has not been exhausted, the
brightness of the light will gradually
decline. Therefore periodic
replacement of the lamp is
necessary.
The intended lamp replacement
interval is 2000 hours, but it is
possible that the lamp may need to
be replaced earlier due to variables
such as a particular lamp’s
characteristics, usage conditions
and the installation environment.
Early preparation for lamp
replacement is encouraged.
A lamp that has exceeded 2000
hours of use has a much greater
chance of exploding. In order to
prevent the lamp from exploding,
the lamp will be automatically shut
off when 2000 hours of use have
been reached.
NOTE:
BThe projector is not supplied
with a replacement lamp unit.
Please ask your dealer for
details. Lamp unit product
no.: ET-LAC80
CAUTION:
BDo not use any lamp unit other
than the one with the product
number indicated above.
NOTE:
BThe usage hours explained
above are for use when the
HIGH setting has been
selected for LAMP POWER in
the OPTION2 menu. If the
LOW setting is selected, the
brightness of the lamp will be
less and life of the lamp can be
extended.
BWhile 2000 hours is the
intended replacement interval,
it is not a period of time
covered by warranty.
NOTE:
BIf the lamp usage time has passed 2000 hours (when LAMP POWER
has been set to “HIGH”), the projector will switch to standby mode after
approximately 10 minutes of operation. The steps ) to - on the next
page should thus be completed within 10 minutes.
Lamp unit cover
Handle
Lamp unit cover fixing screws
Lamp unit fixing screws
A
B