Paradyne and 9820-45M Computer Monitor User Manual


 
SNMP MIBs and Traps, and RMON Alarm Defaults
B-7
9820-A2-GB20-20
June 2000
Trap: warmStart
This trap indicates that the FrameSaver unit has been reset and has stabilized.
Table B-3. warmStart Trap
Trap
What It Indicates Possible Cause
warmStart
FrameSaver unit has just
reinitialized and stabilized
itself.
H Reset command sent.
H Power disruption.
String:
Variable-Binding
String:
‘Unit reset.’
devLastTrapString
(devHealthAndStatus.mib)
Trap: authenticationFailure
This trap indicates that access to the FrameSaver unit was unsuccessful due to
lack of authentication.
Table B-4. authenticationFailure Trap
Trap
What It Indicates Possible Cause
authenticationFailure
Access to the FrameSaver
unit was attempted and
failed.
H SNMP protocol message not
properly authenticated.
H Three unsuccessful attempts
were made to enter a correct
login user ID/password
combination.
H IP Address security is enabled
and a message was received
from the SNMP Manager
whose address was not on the
lost of approved managers.
String:
‘Unauthorized access attempted.’
Variable-Binding
devLastTrapString
(devHealthAndStatus.mib)