Patton electronic 1069 Modem User Manual


 
12
3.4 CONNECTING POWER
The Model 1069 does not have a power switch, so it powers up as soon
as it is plugged in.
An external AC or DC power supply is available separately. This connec-
tion is made via the barrel jack on the rear panel of the Model 1069. No
configuration is necessary for the power supply (See Appendix B for
domestic and international power supply and cord options).
DC power (supplied via the power supply jack to the 1069) must meet
the following requirements; DC power supplied must be regulated
12VDC ±5%, 1.0A minimum. Center pin is +12V. The barrel type plug
has a 2.5/5.5/10mm I.D./O.D./Shaft Length dimensions.
4.0 CONFIGURATION
All configurations for the Model 1069 VDSL2 CPE should be made
through the VDSL2+ DSLAM. The dipswitch included in the Model 1069
is for factory use only.
The Interconnecting cables shall be acceptable for
external use and shall be rated for the proper applica-
tion with respect to voltage, current, anticipated tem-
perature, flammability, and mechanical serviceability.
CAUTION