17
746
Lock tag fail. The RFID tag has not been locked to prevent
reprogramming. This is considered a bad RFID tag. For more
information, refer to the RFIDMP Application Notes or the HF Application
Notes.
747
Time out failure. An RFID command (read, program, etc.) has failed to
complete in the maximum amount of allowed time.
748
Invalid data length/data mismatch from RFID interrogator module. The
RFID interrogator module found a problem with the data received from
the printer. For more information, refer to the RFIDMP Application Notes
or the HF Application Notes.
749
RFID Verify Fail. The RFID verification process failed after writing
(programming) tag. This is considered a bad RFID tag. For more
information, refer to the RFIDMP Application Notes or the HF Application
Notes.
751
Printer did not sense a black mark when expected. Press Escape/Clear
and try to continue printing. Change supply.
752
Printer sensed a mark in the wrong place.
753
Printer sensed a mark that is too long.
754
Check for a ribbon jam or remove any slack in the ribbon by turning the
take-up reel clockwise. Load a new ribbon.
755
Printhead is open. Close the printhead.
756
Load supplies.
757
Load supplies (supply length mismatch). Press Feed/Cut.
758
Either the supply is not seen, the on-demand sensor is broken, or a label
was removed too quickly. Check for a label jam or reload supplies.
763
Waiting to dispense label. Press Feed/Cut.
765
The printhead has less than 8 bad dots and can shift bar code fields to
avoid bad dots. Press Escape/Clear to continue printing.
768
Printhead has more than 8 bad dots within the format area or is not
connected. Replace or connect printhead as necessary.
The printer does not recalibrate (feed a blank label) after any RFID error. Refer to
the RFIDMP Application Notes or the HF Application Notes (on our Web site) for
more information.