![](http://pdfasset.owneriq.net/8/35/83529bc3-945b-4dbf-aba1-fc860f1cbad9/83529bc3-945b-4dbf-aba1-fc860f1cbad9-bg4d.png)
Users Manual Model 545™ Mechanical Trouble Shooting • 75
Non-volatile Memory Reset
It may be necessary from time to time to reset the non-volatile SRAM in the machine. This
can be done by using the DIP switch setting of the TCB at power up. Use the following steps
to perform this function:
1) Power off the machine.
2) Change switch number 2 from its present position.
3) Power on the machine, wait at least 30 seconds, then turn power off.
4) Change switch number 2 back to its original position.
5) Power on the machine and reset the front panel adjustments as needed.