Pelco C2496M Switch User Manual


 
C2462M-B (10/05) 11
8-32 x 1.00
(SUPPLIED)
ADAPTER
RING
BACK
BOX
8-32 X .750
(SUPPLIED)
CEILING/
WALL
4S DEEP ELECTRICAL BOX
Installation in a 4S Deep Electrical Box
Refer to Figure 8 for the following steps.
1. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following:
a. Place fingers on the circular marks located on the sides of the surface mount ring.
b. Pinch the sides.
c. Lift and remove the surface mount ring from the back box.
2. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied).
3. Connect the video cable/wires.
BNC – Connect the BNC connector from the Camclosure to a mating BNC connector.
Twisted Pair – Blue wire = Video +
Gray wire = Video -
4. Connect the power wires.
AC Operation Only – If you are wiring more than one ICS090 Camclosure to the same
transformer, connect one side of the transformer to the red wire on all units, and connect the
other side of the transformer to the black wire on all units. Failure to connect all of the units
the same way will cause the cameras to be out of phase with each other and may produce a
vertical roll when switching between cameras.
5. Attach the back box to the adapter plate with the two 8-32 x .750-inch screws (supplied).
Figure 8. 4S Deep Electrical Box Installation
Voltage Red Wire Black Wire
12 VDC + Ground
24 VAC
~~