Pelco C2496M Switch User Manual


 
C2462M-B (10/05) 17
SERVICE CONNECTOR
An optional 4-foot service/monitor cable, part number ICS090-SC, is available for on-site setup and
adjustments. To use the cable simply plug one end of the cable directly into the service connector
of the ICS090 and connect the other end to any standard BNC (VIDEO IN) connector on a monitor.
To assemble a longer service cable for the ICS090 Series Camclosure, purchase the following parts
at a local electronics supply store:
1 2.5 mm monaural headphone plug
1 CPM 88 miniature coaxial connector
1 RG174/U coaxial cable
To assemble the cable:
1. Attach the CPM 88 miniature coaxial connector to one end of the cable. Follow the directions
supplied with the miniature coaxial connector.
2. Refer to Figure 15 and do the following to attach the 2.5 mm monaural plug to the other end of
the coaxial cable:
a. Remove the support sleeve from the plug, and then slip the support sleeve over the end of
the cable.
b. Prepare the cable.
c. Solder the center connector of the cable to the center pin of the plug.
d. Thread the braid of the cable through the hole in the crimp pin, and then solder the braid to
the top of the crimp pin.
e. Crimp the end of the crimp pin around the cable.
f. Reassemble the support sleeve and the plug.
Figure 15. How to Connect the 2.5 mm Monaural Headphone Plug to the Coaxial Cable
2.5 mm MONAURAL
HEADPHONE PLUG
CENTER CONDUCTOR
BRAID (SHIELD)
COAXIAL
CABLE