Planet Technology ADW-4100 Network Router User Manual


 
ADW-4100 User Manual
8
Figure 3-1: Logon Window
If you can't connect
If ADW does not respond, check the following:
Machine is properly installed, LAN connection is OK, and it is powered
ON. You can test the connection by using the "Ping" command:
Open the MS-DOS window or command prompt window.
Enter the command:
ping 10.0.0.2
If no response is received, either the connection is not working, or
your PC's IP address is not compatible with ADW-4100's IP Ad-
dress. (See next item.)
If your PC is using a fixed IP Address, its IP Address must be within the
range 10.0.0.3 to 10.255.255.254 to be compatible with ADW-4100's
default IP Address of 10.0.0.2. Also, the Network Mask must be set to
255.0.0.0. See Chapter 5 - PC Configuration for details on checking
your PC's TCP/IP settings.
Ensure that your PC and ADW-4100 are on the same network segment.
(If you don't have a router, this must be the case.)