Planet Technology WGS3-2620 Switch User Manual


 
WGS3 Layer 3 Switch User’s Manual
- 28 -
Parameter Default Description
Management Mode Console Mode Indicates that the port settings are for direct console
connection.
Baud Rate 19200 The rate at which data is sent between devices. Options :
9600, 19200 and 38400 baud.
Data Bits 8 bits Sets the data bits of the RS-232 port. Options : 7, 8
Stop Bits 1 bit Sets the stop bits of the RS-232 port. Options : 1, 2
Parity None Sets the parity of the RS-232 port. Options :
none/odd/even
Time-Out 0 If no input is received from the attached device after this
interval, the current session is automatically closed.
Range : 0 - 100 minutes; where 0 indicates disabled
Auto Refresh 10 second Sets the interval before a console session will auto
refresh the console information, such as Spanning Tree
Information, Port Configuration, Port Statistics, and
RMON Statistics. Range : 0, or 5-255 seconds; where 0
indicates disabled