PLUS Vision KG-PS100S Projector User Manual


 
E-60
Replacing the Lamp Cartridge
5
Mount the new lamp cartridge.
(1) Slowly push in the lamp cartridge. (Align it with the screw
holes of the main unit.)
6
Mount the lamp cover.
(1) Insert the edge of the lamp cover into the main unit, then
close the lamp cover.
7
Reset the Lamp Timer.
Connect the power cable, switch on the power, and then reset.
Select [Info.] [Lamp Timer Reset] on the menu and press the ENTER button. There is a change to the initialization
verification display. Press the ENTER button again. See Lamp Timer Reset on Page E-53.
Note:
After reaching the lamp service life, if the lamp is used for more than another 100 hours, it will not be possible to switch on the power. Should
this happen, while the projector is in the standby mode, simultaneously holding down the projectors SOURCE button and AUTO button for
more than 5 seconds will clear the lamp timer. Checking that the STATUS indicator is out will show that the lamp timer has been cleared.
Contact a store that sells the KG-PS100S/KG-PS120X/KG-PS125X for a replacement lamp. Indicate you need a KG-LPS1230 replacement
lamp for the KG-PS100S/KG-PS120X/KG-PS125X (order code 000-155).
(2) Firmly press down on the specified location, then tighten
the 2 screws of the lamp cartridge by turning them clock-
wise.
(2) Tighten the screw of the lamp cover by turning it clockwise.