Polycom 1725-36031-001 Server User Manual


 
SpectraLink 8000 SVP Server: Administration Guide for Mitel and Cisco
PN: 1725-36031-001_H.doc
22
Connect SVP Server to LAN
Using a Cat. 5 cable, connect the NETWORK port on the SVP Server to
the connecting port on the Ethernet switch.
Connect power
1. Once the units have been properly grounded, connect the power
plug from the AC adapter to the jack labeled
PWR on the SVP
Server.
Use only the provided Class II AC Adapter with output 24V DC, 1A.
2. Plug the AC adapter into an 110VAC outlet to apply power to the
SVP Server.
3. Verify that leakage current ("touch" current) is below 250 μA rms
on exposed metal surfaces.
4. If leakage is excessive, power off the system and re-verify ground
path continuity.
5. The system will cycle through diagnostic testing and the LEDs
will blink for about one minute. When the system is ready for use:
The ERROR LED should be off.
Status 1 should be blinking.