Positioning The Media Sensors
23
4. Press the key; “MENU MODE/QUICK SETUP” displays.
NOTE: For a complete description of the Quick Setup menu, see
page 25.
5. Press ↑or ↓
until “Gap/Mark Sensor / Disable*” displays.
6. Press
+ or − until “Gap” displays.
7. Press
↵. An asterisk (*) displays next to “Gap.”
8. Press ↓
until “Auto Calibrate/Run Calibrate” displays.
9. Press
↵. Media advances until it can accurately detect the
label length indicators and then stops at the top-of-form
position. The sensed distance value then displays for one
second.
10. Auto Calibrate is successful when the sensed distance value
correctly matches that of the installed media. For the Gap
option, the sensed distance value is the physical length of one
label plus the length of one gap.
If “GAP NOT DETECTED” or “PAPER OUT” displays, check
the horizontal position of the media sensor (see “Positioning
The Media Sensors” on page 22), press PAUSE, and run Auto
Calibrate again.
11. Press the PAUSE key; “OFFLINE” displays.
12. Press the FEED key several times. Each time you press FEED,
the media should advance one label length and stop.
13. Once the sensed distance value and performance is confirmed,
save it to the desired configuration menu as described below
before powering off the printer.
Saving The Configuration
1. Make sure “OFFLINE” displays on the LCD.
2. Press the key; “MENU MODE/QUICK SETUP” displays.
3. Press ↑or ↓
until “Save Config./1*” displays.
4. Press
↵; “Saving Configuration” displays briefly.
.
.
.
.
.
.