PSC PowerScan Scanner User Manual


 
62 PowerScan Scanner
Enable EAN-13 - selects EAN-13 as an active symbology. EAN-13
options are similar to those of the EAN-8 symbology.
Enable EAN-8 - selects EAN-8 as an active symbology. EAN-8 symbol-
ogy selection also allows options for symbology expansion and reading
of add-ons.
Enable Code 93 - enables Code 93 as an active symbology. The scanner
is preset to recognize all Code 93 bar codes that have between 1 and 50
characters.
Enable Standard 2 of 5 - selects Standard 2 of 5 as an active symbology.
Options for this symbology are similar to Interleaved 2 of 5
features.
IATA - is a special symbology subset of Standard 2 of 5. Enabling IATA
selects this custom code as the active Standard 2 of 5 symbology
(superseding any other Standard 2 of 5 features).
Enable MSI/Plessey - selects MSI/Plessey as an active symbology.
Allows selection of Check Digit or label format (fixed or variable
length) options.
NOTE
Standard 2 of 5 must be enabled in order for
IATA to be active, however, when IATA is
enabled, Standard 2 of 5 will not be decoded.