5 – Fibre Alliance MIB Objects
Link Table
59047-09 C 5-55
A
Return Value
Returns value of 0.
connUnitLinkUnitTypeY (1.3.6.1.3.94.1.12.1.12)
Type of the Fibre Channel connectivity unit as defined in connUnitType.
Syntax
FcUnitType
Access
read-only
Status
mandatory
Return Value
The type of remote device in the link table. For example, switch (4).
connUnitLinkConnIdY (1.3.6.1.3.94.1.12.1.13
This is the Fibre Channel ID of this port. If the connectivity unit is a switch, this is
expected to be a Big Endian value of 24 bits. If this is loop, then it is the ALPA that
is connected. If this is an E_Port, then it will only contain the domain ID. If not any
of those, unknown or cascaded loop, returns all bits set to 1.
Syntax
OCTET STRING (SIZE(3))
Access
read-only
Status
mandatory
Return Value
The remote Fibre Channel address of each entry in the link table.
connUnitLinkCurrIndex (1.3.6.1.3.94.1.12.1.14)
The last used link index.
Syntax
INTEGER