RCA DLA-SX21SE Projector User Manual


 
10
8
TEMP indicator
1
STAND BY indicator
2
OPERATE indicator
3
OPERATE button
4
VOLUME button
5
EXIT button
6
ENTER button
7
HIDE button
p
VIDEO button
q
PC button
w
H-KEYSTONE button
e
V-KEYSTONE button
r
MENU button
t
CURSOR button
(
/
/
/
)
9
LAMP indicator
y
PRESET button
V-KEYSTONE
PC
LAMP
H-KEYSTONE VOL.
VIDEO
TEMP
STAND BY
OPERATE
PRESET
MENU
EXIT
ENTER
HIDE
Control Panel on the Projector
Controls and Features
Indicator Display on the Control Panel
Indicators appear on the Control Panel to indicate the stand-by, operate or cool down mode as well as other operations in running.
For explanations on warning indication for *
1
,*
2
:
*
1
: page 43
*
2
: page 51
STAND BY light on
On stand by mode
OPERATE light on
On operate mode
(In operation/ during projection)
STAND BY blinking
On cool down mode (when cooling lamp)
LAMP blinking*
1
When the lamp expired
(Lamp time over 2000hours)
LAMP light on*
1
When time to replace lamp is near
(Lamp time over 1900hours)
LAMP and STAND BY blinking*
2
When lamp does not light up and unable to
project
LAMP and OPERATE blinking
simultaneously*
2
Lamp turned off during projection
LAMP and TEMP blinking*
2
When circuit does not function properly
(Abnormal circuit functioning)
LAMP and OPERATE blinking
alternately*
2
When lamp is removed
TEMP blinking*
2
When internal temperature is abnormally high
(Abnormal internal temperature)
TEMP and STAND BY blinking*
2
When temperature at exhaust vents is high
(Abnormal external temperature)
All blinking*
2
When inner fan stops (fan lock)
LAMP TEMP
STAND BY
OPERATE
LAMP TEMP
STAND BY
OPERATE
LAMP TEMP
STAND BY
OPERATE
LAMP TEMP
STAND BY
OPERATE
LAMP TEMP
STAND BY
OPERATE
LAMP TEMP
STAND BY
LAMP TEMP
STAND BY
OPERATE
LAMP TEMP
STAND BY
OPERATE
OPERATE
LAMP TEMP
STAND BY
OPERATE
LAMP TEMP
STAND BY
LAMP TEMP
STAND BY
OPERATE
LAMP TEMP
STAND BY
OPERATE
OPERATE