( 24 / 72 )
Chapter 3. Setting Up
To use this emulation pod with your target system, it is necessary to set as follows. Set the following
after removing the upper cover.
• Set the switches in the emulation pod corresponding to the condition of the target system.
• Change the oscillation frequency of the emulation pod.
• Change the input frequency of the OSD oscillation.
• Change the constant number of the data slicer I/O signal circuit.
• Install the A-D conversion bypass capacitor.
3.1 Removing the Upper Cover
The procedure of removing the upper cover is shown below.
(1) Remove the four screws of both sides of this product and lift off the upper cover. (see Figure 3.1)
(2) Set the switches following the descriptions below.
(3) Replace the upper cover and secure the four screws.
Figure 3.1 Removing the upper cover
CAUTION
Notes on Removing the Upper Cover:
• Always shut OFF power when removing the upper cover or setting the switches.
•Do not touch the connector pins of the emulator main unit and the target MCU
connector pins. Static electricity may damage the internal circuits.