3.6 Connecting the PC4701 and Emulation Pod
To connect the emulation pod to the PC4701, use the FLX120-RPD 120-pin flexible cable included
in this product package. Connect the PC4701 side connector of FLX120-RPD to the cable connector
of the PC4701, then secure the FLX120-RPD with the screws.
(1) Connecting the Cable to the PC4701
Figure 3.14 shows how to connect the PC4701 and FLX120-RPD.
Figure 3.14 Connecting PC4701 and FLX120-RPD
CAUTION
Note on Connecting the Cable:
Always shut OFF power before connecting the cable. The power ON state could
destroy internal circuits.
Note on Tightening the Screws:
After connecting the cable to the emulator main unit PC4701, be sure to tighten the
screws mounted in both sides of the connector.