( 22 / 40 )
3.3 Connecting the Emulation Pod Main Unit
The emulation pod for 7906 Group MCUs consists of the following two products.
(1) Emulation pod : M37900T2-RPD-E
(2) Pod probe : M37906T-PRB
It is necessary to connect the M37906T-PRB to the M37900T2-RPD-E for the emulation of 7906
Group MCUs. Figure 3.3 shows how to connect them.
Figure 3.3 Connecting pod probe M37906T-PRB
(1) Unscrew the four screws of M37906T-PRB.
(2) Connect the connectors J3 and J4 of the M37900T2-
RPD-E's FLX100 to the connectors J3 and J4 of the
M37906T-PRB. And connect the connectors J1 and J2
of M37906T2-PRBM to the connectors J5 and J6 of the
M37906T-PRB.
(3) Fix the M37906T-PRB with the four screws.