Rotel RLC-1080 Power Supply User Manual


 
14
RLC-1080 Power Conditioner
Specifications
INPUT
Voltage Range for Operation on Utility 90V – 144V
Nominal Voltage 120 VAC
Allowable Frequency for Operation on Utility 47 – 63 Hz
Rated Input Current 12 Amps
Circuit Breaker Rating 15 Amps
OUTPUT
Number of Outlets 12 (all outlets are surge protected, conditioned,
regulated and battery backed up)
Outlet Type NEMA 5-15R
Rated VA Capacity 1440 VA
Rated Watt Capacity (continuous) 900 Watts
Rated Output Current 12 Amps
BATTERY BACKUP
Transfer Time to Battery During Blackout 7ms typical, 10ms maximum
Battery Type/Quantity Four 12V/9A hr Sealed Lead-Acid, Maintenance Free
Typical Recharge Time to 90% Capacity <8 hrs
Battery Service User replaceable, Hot swappable
Battery Life 2-5 Years (Depending on use, environment,
and temperature)
Battery Runtime
20 minutes (half load) or 7.5 minutes (full load)
(Actual runtimes are determined by load, battery
charge level, battery health and quantity of batteries
installed)
SURGE PROTECTION
Let-Through Voltage Rating <40V
Data Line Protection Jacks RJ45
COAX 3 pair + splitter
Ethernet 1 pair, 10/100bT
Telephone/DSL 2 line, 4 wire with splitter
DC Trigger Two 3.5mm mini-jack plugs (5-30V)
PHYSICAL
Unit Dimensions 17 x 5.25 x 18.55 in.
43.2 x 13 x 47.1 cm
Unit Weight
57 lbs / 26 kgs
CONFORMANCE
Safety Agency Approvals UL1778 (tested to relevant UL1449), CSA,
FCC Part 68 Class B
Warranty 2 years
All specifications are accurate at the time of printing.
Rotel reserves the right to make improvements without notice.