Ruby Tech GS-2124C Switch User Manual


 
GS-2124C User Manual
Publication date: June, 2005
Revision A1
252
gs2124cBandwidthConfEgressBW OBJECT-TYPE
SYNTAX INTEGER(0..1000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Get/Set the egress rate of the bandwidth management
configuration.
The egress rate is from 0 to 1000. "
-- @@ACTION ruby_bandwidth_entry
::= { gs2124cBandwidthConfEntry 7 }
-----------------------------------------------------------------
gs2124cTrapEntry OBJECT IDENTIFIER ::= { gs2124cProduces 20 }
gs2124cModuleInserted NOTIFICATION-TYPE
OBJECTS { ifIndex }
STATUS current
DESCRIPTION
"Send this trap when a moudle is inserted to the system. The OID value
means
the port number."
::= { gs2124cTrapEntry 1 }
gs2124cModuleRemoved NOTIFICATION-TYPE
OBJECTS { ifIndex }
STATUS current
DESCRIPTION
"Send this trap when a moudule is removed from the system. The OID
value means
the port number."
::= { gs2124cTrapEntry 2 }
gs2124cDualMediaSwapped NOTIFICATION-TYPE
OBJECTS { ifIndex }
STATUS current
DESCRIPTION
"Send this trap when the dual media port changed. The OID value means
the port number."
::= { gs2124cTrapEntry 3 }
gs2124cStpStateDisabled NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Send this trap when the operational state of STP is from enabled to
disabled. "
::= { gs2124cTrapEntry 100 }
gs2124cStpStateEnabled NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Send this trap when the operational state of STP is from disabled to
enabled. "
::= { gs2124cTrapEntry 101 }