4.4.2. Gigabit Ethernet (1Gbps) Optical Specifications
Fixed Gigabit Transceivers
Order
Code
Mode
Connector
Type
Cable
Type (µm)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.)
(km)
Power
Budget
(dB)
FG01 MM LC 50/125 850 -9 -2.5 -20 0 0.5 11
FG02 SM SC 9/125 1310 -10 -3 -20 -3 10 10
FG03 SM LC 9/125 1310 -9.5 -3 -21 -3 10 11.5
FG04 SM SC 9/125 1310 -5 0 -20 -3 25 15
FG05 SM LC 9/125 1310 -7 -3 -24 -3 25 17
Table 4.6. Fixed Gigabit Transceivers
SFP Gigabit Transceivers
Order
Code
Mode
Connector
Type
Cable
Type (µm)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.)
(km)
Power
Budget
(dB)
50/125 0.5
FG51 MM LC
62.5/125
850 -9 -2.5 -20 0
0.3
11
FG52 SM LC 9/125 1310 -9.5 -3 -19 -3 10 9.5
FG53 SM LC 9/125 1310 -7 -3 -23 -3 25 16
FG54 SM LC 9/125 1550 0 5 -23 -3 70 23
Table 4.7. SFP Gigabit Transceivers
Notes:
1. Maximum segment length is greatly dependent on factors such as fiber quality, and
the number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.
2. All optical power numbers are listed as dBm averages.
3. F51 transceivers are rated for -40°C to +85°C.
4.5. Operating Environment
Parameter Range Comments
Ambient Operating Temperature -40°C to 85°C
Ambient Temperature as measured from a 30cm
radius surrounding the center of the enclosure.
Table 4.8. Operating Environment
4.6. Mechanical Specifications
Parameter Value Comments
Dimensions
4.83 × 4.40 × 7.00 REF (6.86) inches
122.68 × 111.76 × 177.80 REF (174.24) mm
(Height × Width × Depth)
Weight Approximately 5 lbs (2.3 kg) Weight dependent on module selection.
Ingress Protection IP40
Enclosure Aluminum
Table 4.9. Mechanical Specifications