Runco PL-50XA Projector Accessories User Manual


 
Installation
Runco PlasmaWall Owner’s Operating Manual 21
PRE
L
IMINAR
Y
Digital Video Connection: The PlasmaWall has two HDMI inputs. Connect the DVI
output from the DHD Controller to the DVD/HD3 input, using a DVI-to-HDMI cable.
RGB-HD Connection: Connect the RGBHV output from the DHD Controller to the
PC/RGB input on the PlasmaWall. Use a VGA-to-RGBHV breakout cable with 5 BNC
connectors on the DHD end and a standard, 15-pin, male VGA connector on the
PlasmaWall end.
RS-232 (External Control) Connection: Connect the RS-232 output from the DHD
Controller to the EXTERNAL CONTROL input on the PlasmaWall. Use a standard,
modular telephone cable with RJ11 plugs at both ends. On the PlasmaWall end, use an
RJ11-to-DB9, crossover adapter wired as shown in
Figure 3-4.
Figure 3-4. RS-232 Connection from the DHD Controller to the PlasmaWall
3
4
2, 5
XMT DATA
RCV DATA
REQUEST TO SEND
SIG GND
2
3
7
8
5
RCV DATA
XMT DATA
CLEAR TO SEND
NO CONNECTION
1, 6
1, 9
4
6
SIG GND
DATA SET READY
DATA TERMINAL READY
To/From
DHD
Controller
RJ-11 Male
DB-9 Female
1
5
6
9