COMMAND PARAMETER (min/max) Value stored? DESCRIPTION
!STORE NA YES Stores the current set of values
(all values) into non-volatile
memory
!RESTORE NA YES Restores the stored values
!FACTORY NA YES Restores all values to factory
default levels
!STATUS NA NA Asks the Controller to provide
the hardware information,
current values and system status
to the automation system
!RESTART NA NO Restarts the PFP Controller
(same as turning it on and off)
!ECHO NA NO Enables the Controller to echo
back commands and values to
the automation system
!NOECHO NA NO Disables the Controller's
character echoing
!INSTALLMODEOFF NA NA Disables the Installation menu
(removes it from the main menu)
!INSTALLMODEON NA NA Enables the Installation menu
(enables it on the main menu)
!SERVICEMODEON NA NA Enables the service mode
!SERVICEMODEOFF NA NA Disable the service mode
RGAIN -30/30 NO Adjust the Red level of image
GGAIN -30/30 NO Adjust the Green level of image
BGAIN -30/30 NO Adjust the Blue level of image
ROFFSET -30/30 NO Adjust the Red level of image
GOFFSET -30/30 NO Adjust the Green level of image
BOFFSET -30/30 NO Adjust the Blue level of image
RGamma -30/30 NO Adjust the Red gamma of image
GGamma -30/30 NO Adjust the Green gamma of
image
BGamma -30/30 NO Adjust the Blue gamma of image
IRCODE 013 NO Changes the IR Code Set of the
Controller to 013
IRCODE 215 NO Changes the IR Code Set of the
Controller to 215
IRCODE 510 NO Changes the IR Code Set of the
Controller to 510
IRCODE 918 NO Changes the IR Code Set of the
Controller to 918
IRCODE 0 NO Disables the IR receiver