Samsung SRP-770II Printer User Manual


 
ٻ
ڌڍٻ
8. LED Display
LED display indicates the printer status.
1. Green LED on
- The printer waits for the data from Host (PC) in normal mode.
2. Orange LED on
- It means paper gap sensing error. It becomes on when the printer fails to detect the
paper or paper jam occurred. When fails to detect the paper correctly use
Auto-Calibration function.
3. Red LED on
- The printer has stopped by pressing FEED button. It restarts printing when pressed
again.
4. Green LED blinking
1) TPH (Thermal Printing Head) overheated or ;
2) The printers is waiting for the button input to run Auto-Calibration function.
5. Orange LED blinking
- No paper. Make sure the paper is loaded correctly.
6. Red LED blinking
1) The printer cover is open or ;
2) Auto cutter has error such as paper jam in case of auto cutter built-in model.
9. Pause / Restart
Press FEED button to pause at the middle of labels printing.
1. Pause
- Press FEED once. Printer stops after on-going printing and Red LED becomes on.
2. Restart
- Press FEED once again. It restarts printing in a queue.
ٻ
ڌڎ
10. Gap Sensor Auto-Calibration
Gap sensor auto-calibration is used when the printer does not detect a gap on the label
paper correctly. Generally a printer is set to detect most of gap types but sometimes it fails
to detect and keep feeding the paper without a stop when special paper used. In such case,
use gap sensor auto-calibration function for a proper detection.
1. Make sure that paper roll has been installed properly.
2. Turn on the power while holding down FEED button with cover open.
Then the Green LED blinks.
O
n
3. Close the cover and guide message is printed automatically.
Then a printer waits for input with red LED on.
4. Press FEED button once to initialize gap sensor and set it back to the
factory setting. LED changes to Orange.
5. Press FEED button twice to run auto-calibration function.
LED changes first to Orange and second to Green.
It feeds 2-3 papers while auto-calibration executed.
Make sure to press a button one by one while checking LED changes.
6. Saved sensing value remains valid at power off unless otherwise above
gap sensor initialization is executed again.