SATO 400 Printer User Manual


 
Sensor Type
Command Structure <ESC>IGa
a = 0 Reflective (Eye Mark) sensor
1 See-thru (transmissive) sensor
2 Sensor not used
Example: See above
Placement: Separate data stream sent to printer
Default: Default value set by <ESC>PG command
Command Function To select the label sensing method for a job.
Input to Printer
<ESC>A
<ESC>IG1
<ESC>Z
Printer Output There is no printer output as a result of this command
Special Notes 1. When power is cycled, the value set by this command is lost and
replaced by the default value stored in the EEPROM.
2. To change the value stored in the EEPROM, use the <ESC>PG
Printer Setting command or use the Printer Setting Utility program
contained on the CDROM shipped with the printer.
Section 4. Programming Reference
SATOCT SeriesPrinters9001069A Page4-89